Non-Insulated (Non-IC) Remodeler - 5" Aperture
| Frame-In Kit (Housing) | Reflector Trims | ||||||||||||||||||||||||||||||||||||
| 1003R |
|
||||||||||||||||||||||||||||||||||||
For higher performance and greater flexability in non-insulated ceilings.
For use in non-insulated ceilings up to 2" thick.
Insulation may not be placed above or within 3" of the fixture.
Pre-installed mounting straps allow installation from below without damaging plaster or gypsum board.
Features
- Mounting Ring: .032 (#22 ga.) galvanized steel.
Accommodates existing ceilings up to 2” thick.
Attaches securely to any type of ceiling material without tools using (3) mounting straps provided.
Push-in/twist-out clips hold reflector flush to ceiling.
Includes adhesive backed aperture template. - Junction Box: 2 1/2” X 2 1/2” X 3 1/2” (21 cu. in.) .032 (#22 ga.) galvanized steel.
U.L. listed for 90° C supply wire.
Integral cable clamps permit attachment of non-metallic (#12 or #14 ga.)
Romex® cable without tools or additional connectors.
Attaches to mounting ring without tools. - Socket Housing: Impact extruded aluminum or galvanized steel.
- Socket: Porcelain medium base; nickel plated screw shell.
Pre-wired with #18 ga. SF1 (300 VOLT 200° C) leads to junction box. - Thermal Protector: Meets NEC and U.L. requirements.
Do not install insulation within 3 inches of fixture sides or wiring compartment
nor above fixture in such a manner as to entrap heat.
UL (Suitable for Damp Locations)

