Lytening AirSeal Insulated Ceiling(IC)
3 3/4" Aperture
For dramatic accent and task lighting with MR16 lamps.
Rated for direct contact with insulation. Fully gasketed to minimize air leakage and reduce energy loss.
Complies with restricted airflow requirements of the WSEC and MEC energy codes.
Magnetic transformer is mounted inside housing for easy access.
Compatible Trims: 2005, 2005WH, 2011, 2006.
Features- Housing: .032” (#20 ga.) aluminum. UL listed for direct contact with thermal insulation.
AirSeal® housing minimizes air leak-age to less than 2 CFM at 1.57 PSF (or 75pa),
which complies with Model Energy Code (Section 602.3.3) and Washington State Energy Code (Section 502.4)
and reduces heat loss and condensation in ceiling. Access door for inspection of junction box. - Mounting Frame: .032 (#20 ga.) aluminum. Accommodates ceilings up to 1”
thick. 3/8” deep integral lip.
Locks into position along length of mounting bars with locking screw and bendable slot.
Four slots are positioned 90° apart to simplify alignment. Push-in/twist-out roto-clips hold reflector flush to ceiling. - Junction Box: 2” X 4” X 3 1/2” (22 cu. in.) .032” (#22 ga.) galvanized steel.
UL listed for maximum of 8 (#12 ga.) 1104IC and 6 (#12 ga.) 90°C through branch circuit conductors.
Integral cable clamps permit attachment of nonmetallic (#12 or #14 ga.) Romex® cable without tools or additional connectors. - Mounting Bars: .059” (#16 ga.) galvanized steel. Bars pivot for easy attachment and wire-in below ceiling line.
Bars extend to accommodate 16” to 24“ O.C. joist spacing. Bars can accommodate 12” O.C joist spacing
after a slight field modification (see Instruction Sheet).
2004ICVN features integral nails for secure attachment to wood. Attaches to T-bar ceilings without the need of accessories. - Socket Housing: Impact extruded aluminum, with lamp adjustment assembly allows 35° max. vertical, 358° horizontal adjustment.
- Socket: Field replaceable. Two pin socket, pre-wired with #18 SF1 leads to junction box.
- Thermal Protector: Meets NEC and UL requirements. Integral to transformer. Located inside housing.
- Transformer: Mounted inside housing, magnetic. 120V primary, nominal 12V secondary. Removable from below.